Cold Mountain Supply — wholesale HVAC equipment and materials

HVAC Glossary

The trade's vocabulary, minus the mystery — 55 terms explained in plain counter English.

A2L Refrigerants

The 'mildly flammable' safety class covering R-454B and R-32. Ignition

AFUE

Annual Fuel Utilization Efficiency — the percentage of fuel a furnace

AHRI Match

A certified combination of outdoor unit, indoor coil/air handler, and

Auxiliary Heat Lockout

A thermostat setting that blocks electric strip heat above a chosen ou

B-Vent

Double-wall metal venting for draft-hood and 80%-class gas appliances.

Balance Point

The outdoor temperature where a heat pump's output exactly matches the

Black Iron Pipe

Threaded steel pipe, the traditional material for fuel-gas lines. Asse

Burner Orifice

The precisely drilled brass fitting that meters gas to each burner. Na

CFM

Cubic feet per minute — airflow volume. Residential cooling wants roug

Condensate Trap

The water-seal trap on an evaporator drain that stops air from blowing

Condensing Furnace

A 90%+ AFUE furnace with a secondary heat exchanger that wrings extra

Contactor

The relay that lets 24V thermostat wiring switch the condenser's line-

Core Charge

A deposit built into the price of certain parts — compressors, some mo

CSST

Corrugated Stainless Steel Tubing — flexible gas piping that snakes th

Defrost Cycle

In heating mode the outdoor coil runs below freezing and frosts over;

Design Temperature

The outdoor temperatures a system is sized against — typically the 99%

Draft Inducer

The small blower that pulls combustion air through the heat exchanger

Dual Fuel

A heat pump paired with a gas furnace: the heat pump handles mild weat

ECM Motor

Electronically commutated motor — a variable-speed DC blower motor tha

Encapsulated Crawlspace

A sealed, vapor-barriered, often conditioned crawlspace. It pulls duct

EPA Section 608

The federal certification required to purchase and handle regulated re

Flame Sensor

A rod that proves the burner lit by conducting a microamp current thro

Float Switch

A safety that breaks the cooling call when condensate backs up, before

GWP (Global Warming Potential)

How much heat a gas traps relative to CO₂ over a century. R-410A sits

Hard-Start Kit

A start capacitor plus relay that gives a compressor extra starting to

Heat Exchanger

The sealed metal passages that transfer combustion heat to household a

Heat Kit (Electric Heat Strips)

Resistance heating elements installed in an air handler, sized in kilo

Hot-Surface Igniter

The ceramic element that glows white-hot to light the burner, replacin

HSPF / HSPF2

Heating Seasonal Performance Factor — the heating-side efficiency rati

Hyper-Heat (H2i)

Mitsubishi's enhanced-vapor-injection cold-climate technology — heat p

Line Set

The pair of copper lines connecting outdoor and indoor units: insulate

Load Calculation

The math that determines a building's actual heating and cooling requi

Manifold Pressure

Gas pressure delivered to the burners, measured in inches of water col

Manual D

The ACCA duct-design method — sizing trunk and branch ducts to deliver

Manual J

The ACCA load-calculation procedure that determines how much heating a

MERV Rating

Minimum Efficiency Reporting Value — a filter's ability to capture par

MFD / Microfarad

The unit of capacitance printed on motor capacitors. Dual capacitors s

Mini-Split (Ductless)

A heat pump system connecting an outdoor unit to one or more indoor he

Multi-Zone System

One outdoor unit driving several indoor heads, each independently cont

Net-30 Terms

Trade credit where the invoice is due 30 days after billing. Supply ho

OEM Part

Original Equipment Manufacturer — the exact part the equipment shipped

R-Value

Resistance to heat flow — higher insulates better. On flex duct, the R

Reclaimed Refrigerant

Used refrigerant recovered, processed back to purity spec, and resold

Reversing Valve

The four-way valve that flips a heat pump between heating and cooling

Run Capacitor

The cylindrical component that phase-shifts power to keep compressor a

SEER2

Seasonal Energy Efficiency Ratio, version 2 — cooling efficiency measu

Short Cycling

Equipment starting and stopping in rapid cycles. Causes range from ove

Static Pressure

The resistance the blower pushes against, measured in inches of water

Subcooling

How many degrees the liquid refrigerant is below its condensing temper

Superheat

How many degrees the refrigerant vapor is above its boiling point at a

Two-Stage Equipment

Furnaces or ACs with a low and high output level. Low stage handles mo

TXV (Thermostatic Expansion Valve)

The metering device that regulates refrigerant flow into the evaporato

Variable-Speed / Inverter

Equipment that modulates output continuously instead of cycling on and

Vented Crawlspace

A foundation crawl with open vents to outdoor air — standard in older

Will-Call

Supply-house term for order-ahead counter pickup: call or submit the o
Text NowCall NowOpen Account